Windstorm Listings

Hurricane Product Listings

ProductListingSingle DoorPair of Doors (Same Swinging)
Door GaugeDoor SizeDesign Pressure (PSF)Door GaugeDoor SizeDesign Pressure (PSF)
Advantex H10 Series
Rim Exit Device
Florida Building Code
FL19181

Texas Department of Insurance
DR-842
16Ga Single Door4'0"x8'0"+60/-6016Ga Pair of Doors8'0"x8'0" with Detex H90R mullion+60/-60
3'6"x8'0"+60/-607'0"x8'0" with Detex H90R mullion+60/-60
3'0"x8'0"+60/-606'0"x8'0" with Detex H90R mullion+60/-60
4'0"x7'0"+60/-608'0"x7'0" with Detex H90R mullion+60/-60
3'6"x7'0"+70/-707'0"x7'0" with Detex H90R mullion+70/-70
3'0"x7'0"+70/-706'0"x7'0" with Detex H90R mullion+70/-70
18Ga Single Door4'0"x8'0"+50/-5018Ga Pair of Doors8'0"x8'0" with Detex H90R mullion+50/-50
3'6"x8'0"+50/-507'0"x8'0" with Detex H90R mullion+50/-50
3'0"x8'0"+50/-506'0"x8'0" with Detex H90R mullion+50/-50
4'0"x7'0"+50/-508'0"x7'0" with Detex H90R mullion+50/-50
3'6"x7'0"+65/-657'0"x7'0" with Detex H90R mullion+65/-65
3'0"x7'0"+65/-656'0"x7'0" with Detex H90R mullion+65/-65
Advantex H20 Series
Surface Vertical Rod Exit Device
Florida Building Code
FL19181

Texas Department of Insurance
DR-842
16Ga Single Door4'0"x8'0"+60/-5516Ga Pair of Doors8'0"x8'0"+60/-55
3'6"x8'0"+60/-607'0"x8'0"+60/-60
3'0"x8'0"+60/-606'0"x8'0"+60/-60
4'0"x7'0"+60/-558'0"x7'0"+60/-55
3'6"x7'0"+60/-607'0"x7'0"+60/-60
3'0"x7'0"+60/-606'0"x7'0"+60/-60
18Ga Single Door4'0"x8'0"+50/-4018Ga Pair of Doors8'0"x8'0"+50/-40
3'6"x8'0"+50/-457'0"x8'0"+50/-45
3'0"x8'0"+50/-506'0"x8'0"+50/-50
4'0"x7'0"+50/-408'0"x7'0"+50/-40
3'6"x7'0"+60/-507'0"x7'0"+60/-50
3'0"x7'0"+60/-586'0"x7'0"+60/-58
Advantex H40 Series
Narrow Stile Rim Exit Device
Florida Building Code
FL19181

Texas Department of Insurance
DR-842
16Ga Single Door4'0"x8'0"+60/-6016Ga Pair of Doors8'0"x8'0" with Detex H90R mullion+60/-60
3'6"x8'0"+60/-607'0"x8'0" with Detex H90R mullion+60/-60
3'0"x8'0"+60/-606'0"x8'0" with Detex H90R mullion+60/-60
4'0"x7'0"+60/-608'0"x7'0" with Detex H90R mullion+60/-60
3'6"x7'0"+70/-707'0"x7'0" with Detex H90R mullion+70/-70
3'0"x7'0"+70/-706'0"x7'0" with Detex H90R mullion+70/-70
18Ga Single Door4'0"x8'0"+50/-5018Ga Pair of Doors8'0"x8'0" with Detex H90R mullion+50/-50
3'6"x8'0"+50/-507'0"x8'0" with Detex H90R mullion+50/-50
3'0"x8'0"+50/-506'0"x8'0" with Detex H90R mullion+50/-50
4'0"x7'0"+50/-508'0"x7'0" with Detex H90R mullion+50/-50
3'6"x7'0"+65/-657'0"x7'0" with Detex H90R mullion+65/-65
3'0"x7'0"+65/-656'0"x7'0" with Detex H90R mullion+65/-65
Advantex H50 Series
Narrow Stile Surface Vertical Rod Exit Device
Florida Building Code
FL19181

Texas Department of Insurance
DR-842
16Ga Single Door4'0"x8'0"+60/-5516Ga Pair of Doors8'0"x8'0"+60/-55
3'6"x8'0"+60/-607'0"x8'0"+60/-60
3'0"x8'0"+60/-606'0"x8'0"+60/-60
4'0"x7'0"+60/-558'0"x7'0"+60/-55
3'6"x7'0"+60/-607'0"x7'0"+60/-60
3'0"x7'0"+60/-606'0"x7'0"+60/-60
18Ga Single Door4'0"x8'0"+50/-4018Ga Pair of Doors8'0"x8'0"+50/-40
3'6"x8'0"+50/-457'0"x8'0"+50/-45
3'0"x8'0"+50/-506'0"x8'0"+50/-50
4'0"x7'0"+50/-408'0"x7'0"+50/-40
3'6"x7'0"+60/-507'0"x7'0"+60/-50
3'0"x7'0"+60/-586'0"x7'0"+60/-58
Value Series HV40
Rim Exit Device
Florida Building Code
FL19181

Texas Department of Insurance
DR-842
16Ga Single Door4'0"x8'0"+60/-6016Ga Pair of Doors8'0"x8'0" with Detex H90R mullion+60/-60
3'6"x8'0"+60/-607'0"x8'0" with Detex H90R mullion+60/-60
3'0"x8'0"+60/-606'0"x8'0" with Detex H90R mullion+60/-60
4'0"x7'0"+60/-608'0"x7'0" with Detex H90R mullion +60/-60
3'6"x7'0"+70/-707'0"x7'0" with Detex H90R mullion+70/-70
3'0"x7'0"+70/-706'0"x7'0" with Detex H90R mullion+70/-70
18Ga Single Door4'0"x8'0"+50/-5018Ga Pair of Doors8'0"x8'0" with Detex H90R mullion+50/-50
3'6"x8'0"+50/-507'0"x8'0" with Detex H90R mullion+50/-50
3'0"x8'0"+50/-506'0"x8'0" with Detex H90R mullion+50/-50
4'0"x7'0"+50/-508'0"x7'0" with Detex H90R mullion +50/-50
3'6"x7'0"+65/-657'0"x7'0" with Detex H90R mullion+65/-65
3'0"x7'0"+65/-656'0"x7'0" with Detex H90R mullion+65/-65
Value Series HV50
Surface Vertical Rod Exit Device
Florida Building Code
FL19181

Texas Department of Insurance
DR-842
16Ga Single Door4'0"x8'0"+60/-5516Ga Pair of Doors8'0"x8'0"+60/-55
3'6"x8'0"+60/-607'0"x8'0"+60/-60
3'0"x8'0"+60/-606'0"x8'0"+60/-60
4'0"x7'0"+60/-558'0"x7'0"+60/-55
3'6"x7'0"+60/-607'0"x7'0"+60/-55
3'0"x7'0"+60/-606'0"x7'0"+60/-60
18Ga Single Door4'0"x8'0"+50/-4018Ga Pair of Doors8'0"x8'0"+50/-40
3'6"x8'0"+50/-457'0"x8'0"+50/-45
3'0"x8'0"+50/-506'0"x8'0"+50/-50
4'0"x7'0"+50/-408'0"x7'0"+50/-40
3'6"x7'0"+60/-507'0"x7'0"+60/-50
3'0"x7'0"+60/-586'0"x7'0"+60/-58
H-ECL-230X
Exit Control Lock - Dead Bolt Only
Miami-Dade
NOA #15-0603.15
18Ga Single Door4'0"x7'0"+70/-6518Ga Pair of Doors8'0"x7'0" with Detex H90R mullion+70/-65
Florida Building Code
FL20728.1

Texas Department of Insurance
DR-842
18Ga Single Door4'0"x7'0"+70/-6518Ga Pair of Doors8'0"x7'0" with Detex H90R mullion+70/-65
3'6"x7'0"+70/-657'0"x7'0" with Detex H90R mullion+70/-65
3'0"x7'0"+70/-656'0"x7'0" with Detex H90R mullion+70/-65
H-ECL-230X-TDB
Exit Control Lock - Dead Bolt, Top & Bottom Rods
Miami-Dade
NOA #18-1017.06
16Ga Single Door4'0"x7'0"+80/-8016Ga Pair of Doors8'0"x7'0" with Detex H90R mullion+80/-80
18Ga Single Door4'0"x7'0"+70/-6518Ga Pair of Doors8'0"x7'0" with Detex H90R mullion+70/-65
Florida Building Code
FL20728.1

Texas Department of Insurance
DR-842
16Ga Single Door4'0"x7'0"+80/-8016Ga Pair of Doors8'0"x7'0" with Detex H90R mullion+80/-80
3'6"x7'0"+80/-807'0"x7'0" with Detex H90R mullion+80/-80
3'0"x7'0"+80/-806'0"x7'0" with Detex H90R mullion+80/-80
18Ga Single Door4'0"x7'0"+70/-658Ga Pair of Doors8'0"x7'0" with Detex H90R mullion+70/-65
3'6"x7'0"+70/-657'0"x7'0" with Detex H90R mullion+70/-65
3'0"x7'0"+70/-656'0"x7'0" with Detex H90R mullion+70/-65

FEMA Listings

ProductListingSingle DoorDesign PressurePair of Doors (Same Swinging)Design Pressure
Advantex T27 Series
High Security Relatching Surface Vertical Rod Exit Device
Tested to FEMA 361 (2008) & ICC-500 (2008) Standards per Protocol 4, TornadoAssembly Listing
Dean Steel Doors
3'6"x7'4"
Contact factory for use on other door sizes
Maximum +/- 240PSF by National Wind Institute
FEMA 361 (2008)
Assembly Listing
Dean Steel Doors
7'0"x7'4"
Contact factory for use on other door sizes
Maximum +/- 240PSF by National Wind Institute
FEMA 361 (2008)
Advantex T87 Series
High Security Relatching Concealed Vertical Rod Exit Device